Catalog

8 Result(s)

  • British Standard High-Speed Fuse-Links AC Protection
  • Protistor® BS88-4 size 000 aR/gR (gRB, URC, URD) 690VAC

    British standard Extremely high breaking capacity fuses: Protection of power semiconductors as per IEC standard 60269-1 and -4 690 V voltage rating as per IEC 33 gR class (gRB ratings 50 to 65A) as per VDE 636-23 - Clearing all overloads - Improved safety and protection - Enabling selective coordination with all fuses aR class (URC and URD ratings 75 to 500 A) as per VDE 636-23 and IEC 60269-4 Designs without blown fuse indicator and with separate trip-indicator These fuses are UL Recognized. Read more

  • Protistor® BS88-4 size 10x51 aR (URE) 690VAC

    Extremely high breaking capacity fuses: Protection of power semiconductors as per IEC standard 60269-1 and -4 690V voltage rating as per IEC 33 gR class as per VDE 636-23 and IEC 60269.4 Design without indicator Read more

  • Protistor® BS88-4 size 10x28 aR (URE) 250VAC

    Extremely high breaking capacity fuses: Protection of power semiconductors as per IEC standard 60269-1 and -4 250 V voltage rating as per IEC 33 gR class as per VDE 636-23 and IEC 60269.4 Design without indicator Read more

  • Protistor® BS88-4 size 17x27 aR (URGS/URZ) 250VAC

    Extremely high breaking capacity fuses: Protection of power semiconductors as per IEC standard 60269-1 and -4 250 V voltage rating as per IEC 33 gR class as per VDE 636-23 and IEC 60269.4 Design without indicator Read more

  • Protistor® BS88-4 size 17x49 and 2x17x49 aR/gR (GRB, URB/C/Y/Z) 690VAC

    Extremely high breaking capacity fuses: Protection of power semiconductors as per IEC standard 60269-1 and -4 690V voltage rating as per IEC 33 gR class (current ratings 12 to 90A) as per VDE 636-23 - Clearing all overloads - Improved safety and protection - Enabling selective coordination with all fuses within distribution circuit aR class (current ratings 100A) according to VDE 636-23 and IEC 60269-4 Connection as per: - German standard DIN 43653/00C - British standard BS88-4 These fuses are UL Recognized Read more

  • Protistor® BS88-4 size 17x49 gR (URS) 690VAC

    Extremely high breaking capacity fuses: Protection of power semiconductors as per IEC standard 60269-1 and -4 690V voltage rating as per IEC 33 gR class (current ratings 12 to 90A) as per VDE 636-23 - Clearing all overloads - Improved safety and protection - Enabling selective coordination with all fuses within distribution circuit aR class (current ratings 100A) according to VDE 636-23 and IEC 60269-4 Connection as per: - German standard DIN 43653/00C - British standard BS88-4 These fuses are UL Recognized Read more

  • Protistor® BS88-4 size 36x27 and 2x36x27 aR (GRB, URB/C/Y/Z, URGG) 250VAC

    Extremely high breaking capacity fuses: protection of power semiconductors as per IEC standard 60269-1 and -4 250 V voltage rating complying with IEC 33 aR Class (ratings from 400A to 525AA URGG - 800A to 2050A URGH) complying VDE 0636-23 and IEC 60269-4 2 types comlying with BS 88-4 - without indicator - with separate indicator Read more

  • Protistor® BS88-4 size 36x55 and 2x36x55 aR (URR, URGL) 690VAC

    Extremely high breaking capacity fuses: Protection of power semiconductors as per IEC standard 60269-1 and -4 690V voltage rating as per IEC 33 aR class (current ratings from 75 to 800A) as per VDE 636-23 and IEC 60269.4 Design without indicator Read more

Find what you need fast...


Quick Links