NORMES
CARACTÉRISTIQUES ET AVANTAGES
EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection
(O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications.
EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry.
The MEV100C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 1000VDC, Current rating (In)= 5 to 30A, Interrupting Rating (IR) = 50kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) = 2xIn for a perfect matching with cable protection.
The MEV100A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 1000VDC, Current rating (In)= 60 to 300A, Interrupting Rating (IR) = 100kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) < 3kA or a perfect matching with DC contactor.
Applications
Documents & Ressources
Fiches techniques
Drawings
Compliance
Numéro d'article
MEV100A50-4
Numéro de catalogue
MEV100A50-4
Description
EVpack 1000VDC UL 50A Pouvoir de coupure max. DC: 20 kA @ 1000 V L/R ≤ 1 ms Boulonné
Code EAN / UPC
782001481384
Tension nominale DC UL
1000 V
Courant assigné
50 A
Conforme à ROHS
Oui
AC ou DC
DC
Montage
Boulonné
Pouvoir de coupure DC nominal maximal
20 kA @ 1000 V, L/R ≤ 1 ms
Pouvoir de coupure minimal (MBC)
960 A
Dissipation thermique à la valeur de courant intermédiaire
1.8 W @ 0.5 In
Connexion / Matériel terminal
Laiton étamé
Type de Connexion / Borne
Boulonné
Poids du produit
0.117 kg
Diamètre du produit
25.4 mm
Longueur du produit
111 mm
Quantité du pack de vente
5 EA
Poids du pack de vente
0.585 kg
Largeur du pack de vente
150 mm
Longueur du pack de vente
210 mm
Hauteur du pack de vente
40 mm