NORMES

  • Complies to Automotive IATF 16949:2016 Quality System
  • Power Cycling & Vibration JASO D622

CARACTÉRISTIQUES ET AVANTAGES

EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection
(O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications.
EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry.
The MEV100C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 1000VDC, Current rating (In)= 5 to 30A, Interrupting Rating (IR) = 50kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) = 2xIn for a perfect matching with cable protection.
The MEV100A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 1000VDC, Current rating (In)= 60 to 300A, Interrupting Rating (IR) = 100kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) < 3kA or a perfect matching with DC contactor.

Plus de caractéristiques

Applications

  • EV/HEV
  • Battery pack protection
  • Battery Disconnect Unit (BDU)
  • Battery Management System (BMS)
  • Battery Junction Box for auxiliaries
  • On-board charger

Caractéristiques produit

Numéro d'article

MEV100C20-S  

Numéro de catalogue

MEV100C20-S  

Description

EVpack 1000VDC UL 20A Pouvoir de coupure max. DC: 20 kA @ 1000 V L/R ≤ 1 ms Montage en surface, vissé  

Code EAN / UPC

782001482459  

Tension nominale DC UL

1000   V

Courant assigné

20   A

Conforme à ROHS

Oui  

AC ou DC

DC  

Montage

Montage sur circuit imprimé  

Pouvoir de coupure DC nominal maximal

20 kA @ 1000 V, L/R ≤ 1 ms  

Pouvoir de coupure minimal (MBC)

40   A

Dissipation thermique à la valeur de courant intermédiaire

0.92 W @ 0.5 In  

Connexion / Matériel terminal

Cuivre étamé  

Type de Connexion / Borne

Montage en surface, vissé  

Poids du produit

0.0099   kg

Diamètre du produit

10.3   mm

Longueur du produit

64   mm

Hauteur du produit

14.1   mm

Quantité du pack de vente

80   EA

Poids du pack de vente

0.099   kg

Largeur du pack de vente

0   mm

Longueur du pack de vente

0   mm

Hauteur du pack de vente

0   mm